This store requires javascript to be enabled for some features to work correctly.
Model: HR-J202
When the machine is shipped to the United States and Canada, the buyer does not need to pay tax. When the machine is shipped to the UK, EU, AU, the buyer needs to pay tax. For details, please check Shipping&Warranty>>
Inventory update:
In stock in warehouse in US and CN, shipping time to US address is 3-6 days (8.10)
5-15 days to UK/EU/AU.
Principle
Adopting the Q-Switch ND YAG model, the equipment uses YAG to emit high energy instantaneously which smashing the pigment of pathological tissues, namely the YAG leading explosive effect: High energy emits instantaneously, making particular wavelength penetrating the epidermis and getting into pathological pigment tissues in only 6 nms. Then pigments expand in top speed and explode. The superficial epidermis would be bounded our of the body; another part of the pigments would split into granules which would be engulfed by macrophages, then exclude by the lymphatic system finally. The pigment becomes shallow gradually finally disappear while the surrounding normal skin tissues keep sound as they do not absorb a particular wavelength.
Lasers of different wavelengths achieve different purposes
1064 nm laser is suitable for nevus of ota and coffee spot, freckles, moles, age spots, birthmark, traumatic pigmentation, dispel black tattoo, eyebrow, lip, eye, etc.
532 nm laser is suitable for red or brown tattoos, eyebrow tattoo, lip liner, liner.And it can effectively fade red or brown birthmark and all kinds of shallow spots, etc.
1320nm laser is suitable for skin tender.
Specification
Cooling condition: wind system+closed circulating+cooling system
type: Q-switch ND YAG
Pulse duration: 10ns
Spot diameter:1-8mm
Power: 300W
Wavelengths: 1064 nm & 532 nm and 1320nm
Packing List
1 x Main Unit
1 x Hand-piece
2 x Tips
1 x black doll tip
1 x Water funnel
1 x foot switch
2 x Keys
2 xProtective goggle(for operator and client)
1 x Holder
1 x Power line (we stock 110V-240V power version and US.UK.UA.EU plugs for the country all of the world)
Note: the carbon is not included in the package, but if you need, please contact with us.
Usage
(1)The operation for the tattoo in eyebrow
A customer could not open eyes during Operation, the operator should adjust energy according to the depth of tattoo color, hold the handle and move it to Operation area slowly to make a customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to Operation area, start Operation from the head of an eyebrow to end of the eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear.
(2)Remove eye line
The speed of flashes could be set 4-5HZ, adjust the energy of light to minimum energy, keep a one-finger distance between the head of handle and Operation area. The operator should strictly protect customers eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth.
The operation should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. The operator should press the pledget (panel for eyelid) with forefinger and push up the eyelid, peel down eyelid with the middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also, the customer should close eyes and keep eyeball down-sight inside. The operator should press the pledget (panel for eyelid) with a middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz.
(3)Remove lip line
The speed of flashes could be set 5Hz, keep a 3/4 finger distance between the head of handle and Operation area. It is better to remove black, coffee, deep, red and brown lip line with 1064 head at first time and then, treat again with 532 head.
Notice: All tattoos in lip should be treated in 6 months after making. OR removal Operation will fail. It should have 45-60 days interval to continue next Operation until remove all.
(4)Remove tattoo
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Operation until Operation area seeps a little blood. It should have 45-90 days interval to continue next Operation until remove all.
(5)Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz. Keep 3-4 fingers distance between the head of handle and Operation area. It is better to use high energy for Operation until Operation area seeps a little blood. It is advised to use 1064 head for normal spot and nevus Operation, but for deep color spot and nevus, it is better to use 532 head for Operation. It should have a 15-30 days interval to continue next Operation until remove all.
(6)Remove birthmark
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Operation until Operation area seeps a little blood. It is advised to use 1064 head for birthmark Operation, but for the red and deep color birthmark, it is better to use 532 head for Operation. It should have 45-90 days interval to continue
Quality Assurance
The instrument is warranted for 12 months from the date of purchase (with notes), the handleisguaranteed for 3 months, and the failure (non-human phenomena) within the warranty periodisfree of charge. Any person who exceeds the warranty period may also be responsible for repairs. The cost of spare parts and consumables shall be charged according to the company's regulations(transportation costs shall be borne by the customer). If you need to add or purchase, pleasecontact us. There is no free repair warranty service for the following personal reasons:
- The use of carelessness, beats, falls caused by failure;
- Failure due to lack of proper maintenance;
- Failure caused by incorrect use of the instructions for use.